Projects & studies
Relevant work from the public portfolio, with each case study listed once.
Master’s thesis · Apr 2025 - Nov 2025 · Siemens Energy
Seven months embedded at Siemens Energy Finspång conducting compressible CFD/CHT, high-temperature instrumentation and root-cause analysis for the Pulsatorn dynamic pressure sensor calibration rig.
ANSYS Fluent · CFD/CHT · k-omega SST · NI-DAQ · LabVIEW · Siemens NX
Academic project · 2025 · KTH coursework
Latent-heat mobile thermal energy storage lab characterising RT60 HC discharge behaviour, measurement interpretation and thermal-response trends.
PCM · Thermal lab · Data analysis
Academic project · 2025 · KTH coursework
Battery discharge lab comparing Ni-MH, Li-Po and lead-acid cells through C-rate behaviour, voltage curves and performance interpretation.
Battery testing · C-rate · Python · Lab data
Independent project · Portfolio project
Low-cost vibration workflow using phone accelerometer data, filtering, FFT/PSD, spectrograms and report generation.
Python · FFT · PSD · HTML reports
Academic project · Aug 2019 · APJ Abdul Kalam Technological University
Compressor-free refrigeration concept based on Peltier cooling with no rotary power-consuming component.
Thermoelectric cooling · Temperature sensing · Prototype design · Design report
Work & related roles
Professional experience, internships and relevant student responsibilities are labelled separately.
Contract · Apr 2025 - Nov 2025
Seven months embedded at Siemens Energy Finspang in the Fluid Dynamic Lab. Conducted numerical investigation of steady-state thermo-fluid performance of a reducer geometry for a high-temperature dynamic pressure sensor calibration rig (Pulsatorn). Built compressible CFD and conjugate heat transfer models in ANSYS Fluent (k-omega SST), conducted three-level mesh independence study, and applied Biot number analysis to decompose thermal performance. Identified flow-regime asymmetry between geometry variants (Ma 0.990 near-choked vs Ma 1.006 supersonic vena contracta). Also commissioned NI-DAQ measurement chains, modified LabVIEW VIs, ran independent test campaigns at up to 700 C, and conducted a formal root cause analysis of a heater failure resulting in an approved project scope revision. Used Siemens NX and Teamcenter PLM2020 throughout. Supervisor: Prof. Jens Fridh, KTH. Thesis: TRITA-ITM-EX 2026:14.
ANSYS Fluent · NI-DAQ · LabVIEW · Siemens NX · Teamcenter PLM2020 · Conjugate Heat Transfer · Compressible CFD · Root Cause Analysis
Internship · Jun 2018
Industrial exposure to automation, hydraulics and pneumatics.
Education & coursework
Academic foundation · 2023–2026 · KTH Royal Institute of Technology
Master’s programme in heat and power, energy systems and numerical methods. Thesis completed; 115 hp recorded in the May 2026 transcript.
Academic foundation · 2017–2021 · College of Engineering Perumon / APJ Abdul Kalam Technological University
Mechanical engineering foundation with coursework, design competitions and the final-year interactive robot project.
Relevant courses
- MJ2426Applied Heat and Power TechnologyKTH Royal Institute of Technology
- MJ2386Energy Storage TechnologyKTH Royal Institute of Technology
- MJ232XDegree Project in Heat and Power TechnologyKTH Royal Institute of Technology
- ME304Dynamics of MachineryAPJ Abdul Kalam Technological University
- EE311Electrical Drives & Control for AutomationAPJ Abdul Kalam Technological University
- ME376Maintenance EngineeringAPJ Abdul Kalam Technological University
- ME407MechatronicsAPJ Abdul Kalam Technological University
- ME312Metrology & InstrumentationAPJ Abdul Kalam Technological University
Full course descriptions and project connections
Further learning & certifications
Training records support the work above; they are not substitutes for project evidence. Issuer links are not credential-verification links.
Noise, Vibration & Harshness (NVH) TestingCoursera · Feb 2026
Credential ↗Damping Strategies for NVHCoursera · Feb 2026
Credential ↗SSG Entre Siemens Energy ABSSG Standard Solutions Group · Jan 2025 · Expires Jan 2028
Issuer ↗
Publications & supporting resources
Supporting material · TRITA-ITM-EX 2026:14
Numerical investigation of the high-temperature reducer, with the documented experimental limitations.
Supporting material · Research direction
Experimental–numerical questions, methods and proposed directions; not completed research claims.
Academic CV (PDF)
Scope & limitations
Commissioning and laboratory interpretation are not equivalent to accredited calibration. The Siemens campaign was limited by a heater failure; low-cost vibration work is not certified condition monitoring.